Advanced IC Engineering Inc.

Home

Engineering Services

Reference

V.35REF

RS232C REF

RS449 (V.11) REF

RS530 REF

PID ALGORITHM REF

Test - MATS

UMATS DETAIL

V35MATS DETAIL

Test - ACT128

Com - Exchanger

Exchanger Detail

Industrial

FOX DETAIL

CONVERTER DETAIL

Twisted Trains

HOT BOX DETAILS

DEFECT DETECT REF

Shipping

About

Contact

Reseller

Exchanger

Interface Converter / Modem Eliminator / Line Driver

Technical Reference


Exchanger Models
EX01 V.35 TO RS232
EX01C V.35 TO RS232 WITH INTERNAL CLOCK
EXO3 V.35 TO RS530
EXO3C V.35 TO RS530 WITH INTERNAL CLOCK
EX04C V.35 TO V.35 WITH INTERNAL CLOCK
EX06 RS232 T0 RS530
EX06C RS232 TO RS530 WITH INTERNAL CLOCK
EX07C RS232 TO RS232 WITH INTERNAL CLOCK
EX10C RS530 TO RS530 WITH INTERNAL CLOCK

Operation

The ADVICE Exchanger series is a combination of a interface converter, modem eliminator, and line driver in a single package. Each unit provides two of the following interfaces: RS232, V.24, RS449, RS530, V.11, or V.35. The Exchanger provides the following functions:

  • Interface Converter - The Exchanger will provide conversion from each of the selected interfaces to the other in all modes of operation. Each port (A and B) converts the signals to TTL to the crossover section of the unit. At this point all options are selected. Signals are converted from TTL back to the proper interface on the opposite port.
  • Modem Eliminator - The clocking option allow for use as a modem eliminator. The basic configuration is set up as DCE to DCE and clocks are provided by the on board (n x 56K, n x 64K) clock. Other clocking options are available, such as Terminal Timing, Mixed Clocks and Single Point Clock.
  • Line Driver - Each interface is completely re-powered, which allows for longer runs. Depending on the interface and speed this could add 100 meters to the communication length.

Setting the Jumpers

The basic operation revolves around the two ports (A and B). The first set of jumpers after each port select the operation of the port. DCE (Connects to a DTE) or DTE (Connect to a DCE). This will select the proper pins for TD, RD, TC, RC, XTC, RTS, CTS, DTR, DSR, DCD and sets up the interface. Port A is controlled by Jumpers J3,J4,J5. Port B is controlled by Jumpers J7,J9,J10. These jumpers must be moved as a group, ie. must be all set to DTE or DCE without mixing.

The next Jumpers J2 and J11 select the operation of RTS, CTS, as either Local or Remote (RMT). Local means that Port A RTS will be directed back to Port A CTS and Port B RTS will be directed to Port B CTS. Remote means that the signals will cross from port A to Port B. Depending on the mode (DCE or DTE) of each port the signal connects to the correct pin as follows:

  • Local mode:
    • Port A CTS connects to Port A RTS
    • Port B CTS connects to Port B RTS
  • Remote mode:
    • Port A DCE, Port B DTE
    • Port A CTS connects to Port B CTS
    • Port A RTS connects to Port B RTS
    • Port A DCE, Port B DCE
    • Port A CTS connects to Port B RTS
    • Port A RTS connects to Port B CTS
    • Port A DTE, Port B DTE
    • Port A RTS connects to Port B CTS
    • Port A CTS connects to Port B RTS
    • Port A DTE, Port B DCE
    • Port A RTS connects to Port B RTS
    • Port A CTS connects to Port B CTS

The next set of jumpers (J16,J15) select operation of DSR and DTR. This operation is similar to RTS and CTS. These jumpers must be moved as a set, ie. Local or RMT only.

  • Local mode:
    • Port A DSR connects to Port A DTR
    • Port B DSR connects to Port B DTR.
  • Remote mode:
    • Port A DCE, Port B DTE
    • Port A DSR connects to Port B DSR
    • Port A DTR connects to Port B DTR
    • Port A DCE, Port B DCE
    • Port A DSR connects to Port B DTR
    • Port A DTR connects to Port B DSR
    • Port A DTE, Port B DTE
    • Port A DSR connects to Port B DTR
    • Port A DTR connects to Port B DSR
    • Port A DTE, Port B DCE
    • Port A DSR connects to Port B DSR
    • Port A DTR connects to Port B DTR

Clocking:

Jumpers J24 and J23 select clock source for Ports A and Ports B. These are typically moved in pairs, but some strange clocking options can be achieved by not doing so. "IN" refers to the on-board internal Nx8000 Hz clock if your unit is so optioned. If you are not sure, check Y1 if there is a crystal oscillator installed you have it. "EXT" allows you to connect to the external clock sources.

Jumper J25 allows for a common clock source from either Port A or B External Transmit Clock. Further clocking sources are controlled by J19,20,17,22,18,21. The following is a list of examples of how to set up the clocks. It is important to determine the mode of the DTE/DCE selector first for each port as these control the direction of signals from and to the connectors.

Clock Configurations

Normal Interface Converter
Port A - DTE
Port B - DCE
Clock - DCE TO DTE
J19 NOR
J20 NOR
J17 NOR
J22 NOR
J18 NOR
J21 NOR
J23 REMOVE JUMPER
J24 REMOVE JUMPER
J25 A
Normal Interface Converter
Port A - DCE
Port B - DTE
Clock - DCE TO DTE
J19 NOR
J20 NOR
J17 NOR
J22 NOR
J18 NOR
J21 NOR
J23 REMOVE JUMPER
J24 REMOVE JUMPER
J25 A
Modem Eliminator, Internal Clock
Port A - DCE
Port B - DCE
Clock - Nx8000
J19 NOR
J20 NOR
J17 NOR
J22 NOR
J18 NOR
J21 NOR
J23 INT
J24 INT
J25 A
Back to Back DCE Devices
Port A - DTE
Port B - DTE
Clock - EXTCA
J19 SP
J20 SP
J17 SP
J22 SP
J18 SP
J21 SP
J23 EXT
J24 EXT
J25 A
Back to Back DCE Devices
Port A - DTE
Port B - DTE
Clock - EXTCB
J19 SP
J20 SP
J17 SP
J22 SP
J18 SP
J21 SP
J23 EXT
J24 EXT
J25 B
Modem Eliminator
External Clock from Port A
Port A - DCE
Port B - DCE
Clock - EXTCA
J19 SP
J20 SP
J17 SP
J22 SP
J18 SP
J21 SP
J23 EXT
J24 EXT
J25 A

Front Panel

The front panel can indicate many problems. First each port must be optioned (DTE or DCE). This is what the port on the Exchanger is optioned to appear as not what it is connected to. (ie. A port optioned as a DTE will typically connect to a DCE device.)

The Data LEDs are tri-state and should toggle between red and green, giving a orange color when data is present. If they are stuck either Red or Green something is wrong with the data path. Note: These LEDs will turn more red as the speed increases.

The TC and RC LEDs are tri-state and should toggle between red and green, giving a orange color when clocks are present. If they are stuck either Red or Green something is wrong with the clock set up or clocks are not present at the interface. Note: These LEDs will turn more red as the speed increases.

Rear Panel

The rear panel has two connectors for the interfaces and a subminiature jack for the power. The Exchanger has on-board power regulation so only a unregulated supply is needed. Refer to the technical spec's for more detail.

Setting the Options

To change options remove the two screws located on the bottom of the unit and slide the case lid off. Refer to the other section of this manual for detail of the jumper settings. Refer to the Exchanger Jumper Routings chart for how the signals are routed.

Interface Connections

Signal RS232 V.35 RS530 RS449 Type
TD 2       UNBALANCED
TDA   P 2 4 BALANCED PAIR
TDB   S 14 22 BALANCED PAIR
RD 3       UNBALANCED
RDA   R 3 6 BALANCED PAIR
RDB   T 16 24 BALANCED PAIR
TC 15       UNBALANCED
TCA   Y 15 5 BALANCED PAIR
TCB   AA 12 23 BALANCED PAIR
RC 17       UNBALANCED
RCA   V 17 8 BALANCED PAIR
RCB   X 9 26 BALANCED PAIR
XTC 24       UNBALANCED
XTCA   U 24 17 BALANCED PAIR
XTCB   W 11 35 BALANCED PAIR
RTS 4 C     UNBALANCED
RTSA     4 7 BALANCED PAIR
RTSB     16 25 BALANCED PAIR
CTS 5 D     UNBALANCED
CTSA     5 9 BALANCED PAIR
CTSB     13 27 BALANCED PAIR
DSR 6 E     UNBALANCED
DSRA     6 11 BALANCED PAIR
DSRB     22 29 BALANCED PAIR
DTR 20 H     UNBALANCED
DTRA     20 12 BALANCED PAIR
DTRB     23 30 BALANCED PAIR
DCD 8 F     UNBALANCED
DCDA     8 13 BALANCED PAIR
DCDB     10 31 BALANCED PAIR
GND 7 B 7 19 POWER
CONNECTOR DB25S M.34 DB25S DB37S  

Internal Clock Settings

If your unit has the optional internal clock it can be set for any frequency from 16 kHz to 2.048 MHz in 8 kHz increments. However, don't expect an RS232 interface to operate at speeds above 128 kbps. Set the dip switches to the following positions (open/closed) to obtain the desired frequency.

  • C = On, Closed
  • O = Open, Off
Speed 12345678
   
16K COOOOOOO
24K OCOOOOOO
32K CCOOOOOO
40K OOCOOOOO
48K COCOOOOO
56K OCCOOOOO
64K CCCOOOOO
72K OOOCOOOO
80K COOCOOOO
88K OCOCOOOO
96K CCOCOOOO
104K OOCCOOOO
112K COCCOOOO
120K OCCCOOOO
128K CCCCOOOO
136K OOOOCOOO
144K COOOCOOO
152K OCOOCOOO
160K CCOOCOOO
168K OOCOCOOO
176K COCOCOOO
184K OCCOCOOO
192K CCCOCOOO
200K OOOCCOOO
208K COOCCOOO
216K OCOCCOOO
224K CCOCCOOO
232K OOCCCOOO
240K COCCCOOO
248K OCCCCOOO
256K CCCCCOOO
264K OOOOOCOO
272K COOOOCOO
280K OCOOOCOO
288K CCOOOCOO
296K OOCOOCOO
304K COCOOCOO
312K OCCOOCOO
320K CCCOOCOO
328K OOOCOCOO
336K COOCOCOO
344K OCOCOCOO
352K CCOCOCOO
360K OOCCOCOO
368K COCCOCOO
376K OCCCOCOO
384K CCCCOCOO
392K OOOOCCOO
400K COOOCCOO
408K OCOOCCOO
416K CCOOCCOO
424K OOCOCCOO
432K COCOCCOO
440K OCCOCCOO
448K CCCOCCOO
456K OOOCCCOO
464K COOCCCOO
472K OCOCCCOO
480K CCOCCCOO
488K OOCCCCOO
496K COCCCCOO
504K OCCCCCOO
512K CCCCCCOO
Speed 12345678
520K OOOOOOCO
528K COOOOOCO
536K OCOOOOCO
544K CCOOOOCO
552K OOCOOOCO
560K COCOOOCO
568K OCCOOOCO
576K CCCOOOCO
584K OOOCOOCO
592K COOCOOCO
600K OCOCOOCO
608K CCOCOOCO
616K OOCCOOCO
624K COCCOOCO
632K OCCCOOCO
640K CCCCOOCO
648K OOOOCOCO
656K COOOCOCO
664K OCOOCOCO
672K CCOOCOCO
680K OOCOCOCO
688K COCOCOCO
696K OCCOCOCO
704K CCCOCOCO
712K OOOCCOCO
720K COOCCOCO
728K OCOCCOCO
736K CCOCCOCO
744K OOCCCOCO
752K COCCCOCO
760K OCCCCOCO
768K CCCCCOCO
776K OOOOOCCO
784K COOOOCCO
792K OCOOOCCO
800K CCOOOCCO
808K OOCOOCCO
816K COCOOCCO
824K OCCOOCCO
832K CCCOOCCO
840K OOOCOCCO
848K COOCOCCO
856K OCOCOCCO
864K CCOCOCCO
872K OOCCOCCO
880K COCCOCCO
888K OCCCOCCO
896K CCCCOCCO
904K OOOOCCCO
912K COOOCCCO
920K OCOOCCCO
928K CCOOCCCO
936K OOCOCCCO
944K COCOCCCO
952K OCCOCCCO
960K CCCOCCCO
968K OOOCCCCO
976K COOCCCCO
984K OCOCCCCO
992K CCOCCCCO
1000K OOCCCCCO
1008K COCCCCCO
1016K OCCCCCCO
1024K CCCCCCCO
Speed 12345678
1032K OOOOOOOC
1040K COOOOOOC
1048K OCOOOOOC
1056K CCOOOOOC
1064K OOCOOOOC
1072K COCOOOOC
1080K OCCOOOOC
1088K CCCOOOOC
1096K OOOCOOOC
1104K COOCOOOC
1112K OCOCOOOC
1120K CCOCOOOC
1128K OOCCOOOC
1136K COCCOOOC
1144K OCCCOOOC
1152K CCCCOOOC
1160K OOOOCOOC
1168K COOOCOOC
1176K OCOOCOOC
1184K CCOOCOOC
1192K OOCOCOOC
1200K COCOCOOC
1208K OCCOCOOC
1216K CCCOCOOC
1224K OOOCCOOC
1232K COOCCOOC
1240K OCOCCOOC
1248K CCOCCOOC
1256K OOCCCOOC
1264K COCCCOOC
1272K OCCCCOOC
1280K CCCCCOOC
1288K OOOOOCOC
1296K COOOOCOC
1304K OCOOOCOC
1312K CCOOOCOC
1320K OOCOOCOC
1328K COCOOCOC
1336K OCCOOCOC
1344K CCCOOCOC
1352K OOOCOCOC
1360K COOCOCOC
1368K OCOCOCOC
1376K CCOCOCOC
1384K OOCCOCOC
1392K COCCOCOC
1400K OCCCOCOC
1408K CCCCOCOC
1416K OOOOCCOC
1424K COOOCCOC
1432K OCOOCCOC
1440K CCOOCCOC
1448K OOCOCCOC
1456K COCOCCOC
1464K OCCOCCOC
1472K CCCOCCOC
1480K OOOCCCOC
1488K COOCCCOC
1496K OCOCCCOC
1504K CCOCCCOC
1512K OOCCCCOC
1520K COCCCCOC
1528K OCCCCCOC
1536K CCCCCCOC
Speed 12345678
1544K OOOOOOCC
1552K COOOOOCC
1560K OCOOOOCC
1568K CCOOOOCC
1576K OOCOOOCC
1584K COCOOOCC
1592K OCCOOOCC
1600K CCCOOOCC
1608K OOOCOOCC
1616K COOCOOCC
1624K OCOCOOCC
1632K CCOCOOCC
1640K OOCCOOCC
1648K COCCOOCC
1656K OCCCOOCC
1664K CCCCOOCC
1672K OOOOCOCC
1680K COOOCOCC
1688K OCOOCOCC
1696K CCOOCOCC
1704K OOCOCOCC
1712K COCOCOCC
1720K OCCOCOCC
1728K CCCOCOCC
1736K OOOCCOCC
1744K COOCCOCC
1752K OCOCCOCC
1760K CCOCCOCC
1768K OOCCCOCC
1776K COCCCOCC
1784K OCCCCOCC
1792K CCCCCOCC
1800K OOOOOCCC
1808K COOOOCCC
1816K OCOOOCCC
1824K CCOOOCCC
1832K OOCOOCCC
1840K COCOOCCC
1848K OCCOOCCC
1856K CCCOOCCC
1864K OOOCOCCC
1872K COOCOCCC
1880K OCOCOCCC
1888K CCOCOCCC
1896K OOCCOCCC
1904K COCCOCCC
1912K OCCCOCCC
1920K CCCCOCCC
1928K OOOOCCCC
1936K COOOCCCC
1944K OCOOCCCC
1952K CCOOCCCC
1960K OOCOCCCC
1968K COCOCCCC
1976K OCCOCCCC
1984K CCCOCCCC
1992K OOOCCCCC
2000K COOCCCCC
2008K OCOCCCCC
2016K CCOCCCCC
2024K OOCCCCCC
2032K COCCCCCC
2040K OCCCCCCC
2048K CCCCCCCC

Specifications

V.35, RS530 Balanced Level Converters:

  • Input:
    • Common Mode Range: +/- 0.2 to 14 V max.
    • Impedance: 150 Ohms
    • Protection: 2 kV ESD
  • Output:
    • Common Mode Range: 0 to 5.0 V max.
    • Current Capacity: +/- 150 mA
    • Protection: Thermal Shutdown

V.35, RS232 Unbalanced Level Converters:

  • Input:
    • Common Mode Range: +/- 3 to 25 V max.
    • Impedance: 2 kOhms
    • Protection: 2 kV ESD
  • Output:
    • Protection: Thermal Shutdown Common Mode Range: +/- 10 V
    • Current Capacity: 100 mA

Power

  • Wallmount power unit: (UL/CSA)
    • Input: 120VAC, 60Hz, 3W
    • Output: 9VDC, 500mA

Dimensions

  • 8 x 6.3 x 2 in., 20 x 16 x 5 cm